Radiation detector

Radiation detector specifications
Detector - scintillation plastic (50х40 mm)
Measurement range of the ambient dose equivalent rate - 20 nSv/h – 1 Sv/h
Relative measurement error limit - ±20%
Energy dependence relative to 662 keV (¹³⁷Cs) - ±25% (30 keV – 3 MeV)
Gamma sensitivity ²⁴¹Am/ ³⁷Cs/ ⁶⁰Co - 3200/ 530/ 270 cps⁻¹/ µSv ⁻¹
Protection rating - IР64
Interface - RS 232
Operational temperature - from -40°С to +50°С
Dimensions, weight - Ø60х200 mm, 0.65 kg

The scintillation wide-band intelligent X-ray and gamma-radiation detection unit is designed to measure the ambient equivalent dose rate and the dose of continuous X-ray and gamma radiation in the energy range 15 keV - 3 MeV from 50 nSv / h to 10 Sv / h. The device is installed onboard the UAV as a payload and allows to receive the high accuracy geo-referenced data via telemetry transmission links.

Features:
- X-ray and gamma radiation sources detection
- Represents an intelligent detection unit (RS232 interface)
- System of built-in LED stabilization of the measuring path, thus eliminating the need for a radioactive check source
- Operation in a wide temperature range in the field (IP64)
- Dust and water resistant design